{"product_id":"milwaukee-mw180-max-5-in-1-bench-meter-ph-orp-ec-tds-nacl-temp-logging","title":"Milwaukee MW180 MAX pH\/mV\/EC\/TDS\/NaCl\/Temp Bench Meter with Logging","description":"\u003ch1\u003e\u003cstrong\u003eLab Grade. High Performance. Automated. Tough.\u003c\/strong\u003e\u003c\/h1\u003e\n\u003cp\u003eThe Milwaukee MW180 5-in-1 MAX pH\/ORP\/EC\/TDS\/NaCl\/Temp. Logging Bench Meter has won fans around the world with its reliable, fast and simple operation as well as its tough, sleek design and small benchtop footprint. It is accurate to\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"single-product-meta-item-value\"\u003e± 1% of reading for EC\/TDS\/NaCl and up to +\/-0.002 pH,\u003cspan\u003e \u003c\/span\u003e\u003c\/span\u003e with automatic or manual temperature compensation and a built in dedicated GLP key. Ideal for use by education, horticulture, labs, food processing, water treatment and many other applications with challenging pH\/ORP\/EC\/TDS\/NaCl\/Temp. measurement needs.\u003c\/p\u003e\n\u003ch2\u003eWhat People Are Saying\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e\"Amazingly accurate, the best meter I have used so far.\"\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\"Very satisfied, very accurate, rugged device that calibrates easily.\"\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\"Rarely needs to be calibrated and gives perfect readings every time.\"\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\"Killer tool, good value.\"\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\"Logging data is easy-to-use and download.\"\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\"Love the GLP function.\"\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\"Logging functions increase the reliability of the data.\"\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\"Easy to Clean.\"\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eSummary\u003c\/h2\u003e\n\u003cp\u003eThe Milwaukee MW180 5-in-1 MAX pH\/ORP\/EC\/TDS\/NaCl\/Temp. Bench Logging Meter is preferred by people testing samples in various applications.  The easy-to-use logging feature allows data collection without messy notes and errors. From aquaculture, environmental, research to educators, the MI180 MAX is your cost effective meter for fast, accurate readings.\u003c\/p\u003e\n\u003cp\u003eThe Milwaukee MAX pH\/ORP\/EC\/TDS\/NaCl\/Temp. Bench meter offers:\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003ePeople choose the MW180 5-in-1 MAX pH\/ORP\/EC\/TDS\/NaCl\/Temp. Bench Logging Meter to improve the accuracy and efficiency of their testing program. With easy 1 point EC\/NaCl and up to 3 point pH calibration, 7 memorized standard pH buffer choices, 6 memorized EC calibration solutions 2 point temperature calibration, the meter can be quickly calibrated to a higher temperature accuracy compared to other meters and it provides more accurate temperature compensation readings than a one point calibration. The MW180 5-in-1 MAX Bench Meter is accurate to\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"single-product-meta-item-value\"\u003e± 1% of reading for EC\/TDS and NaCL\u003c\/span\u003e. \u003c\/p\u003e\n\u003cp\u003eThe meter comes with MA814DB\/1 (4 ring) conductivity probe, lab grade MA917B\/1 pH electrode and temperature sensor MA831R, allowing the meter to automatically adjust the pH\/ORP\/EC\/TDS\/NaCl reading for the effect of temperature (ATC).\u003c\/p\u003e\n\u003cp\u003eThe meter can also be used as a very accurate thermometer with accuracy +\/-0.4°C (+\/-0.8°F)\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eToughness\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe rugged meter is built to take knocks and has a sleek design that includes a small benchtop footprint .\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eLow maintenace\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe MW180 MAX pH\/ORP\/EC\/TDS\/NaCl\/Temp. Bench Logging Meter comes with the Milwaukee MA814DB\/1 combination EC sensor and MA917B\/1 pH electrode. They are Milwaukee's top selling lab grade EC and pH probes for a reason. Designed to be both low maintenance and able to withstand more challenging samples. The MA814DB\/1 and MA917B\/1 are ideal for use in horticulture, aquaculture, environmental labs, water treatment\/conditioning and many other applications. \u003c\/p\u003e\n\u003ch2\u003eDesign features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFast easy to read results with large duel level digital LCD readout.\u003c\/li\u003e\n\u003cli\u003eExtreme accuracy to +\/-0.002 pH and 1% of reading for EC\/TDS\/NaCl |+\/- 0.4°C (+\/-0.8°F). \u003c\/li\u003e\n\u003cli\u003eExtended ranges for pH\/ORP\/EC\/TDS\/NaCl.\u003c\/li\u003e\n\u003cli\u003eLightweight, sleek design featuring a small benchtop footprint.\u003c\/li\u003e\n\u003cli\u003eSimple easy-to-use logging and RS232\/USB (opto-isolated) download functions.\u003c\/li\u003e\n\u003cli\u003eGLP data, date and time.\u003c\/li\u003e\n\u003cli\u003eLog-on-demand or auto. up to 50 records  each parameter. \u003c\/li\u003e\n\u003cli\u003eEasy measurement: just place the probe(s) in the sample, gently stir and wait for the reading to stabilize.\u003c\/li\u003e\n\u003cli\u003eUp to 3 point pH automatic calibration, simple single point factor calibration for EC\/TDS\/NaCl, and two point for temperature allowing increased accuracy.\u003c\/li\u003e\n\u003cli\u003eRugged low maintenance, high performance, easy-to-clean pH\/EC\/TDS\/NaCl\/Temp probes.\u003c\/li\u003e\n\u003cli\u003eBuilt in temperature sensor. \u003c\/li\u003e\n\u003cli\u003e12VDC power supply (included).\u003c\/li\u003e\n\u003cli\u003eTemperature compensation automatic or manual. \u003c\/li\u003e\n\u003cli\u003eInternal clock date to keep track of different time-dependent functions (calibration, timestamp,calibration time out).\u003c\/li\u003e\n\u003cli\u003e3 feet probe cables for extra flexibility when testing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMA917B\/1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003epH electrode,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMA831R\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003etemperature probe and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMA814DB\/1\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eincluded.\u003c\/li\u003e\n\u003cli\u003eORP Probes sold separately. \u003c\/li\u003e\n\u003cli\u003eIncludes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMA9315\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eelectrode holder, pipets, initial calibration solutions, software and all cables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCare, Use and Cleaning\u003c\/h2\u003e\n\u003cp\u003epH\/EC\/TDS meters usually start performing poorly because of problems with the sediment on the conductivity probe's rings or build up on the glass pH bulb. The dirt on the EC probe rings or on the ph bulb can change impedance. Cleaning the rings is simple.  Slide the plastic shield off and clean with DI water and soft cloth to keep your readings accurate. For pH, simply soak the pH electrode in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMA9016\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecleaning solution.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCleaning and Storage\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAll pH\/ORP sensors have a limited life and response time gets longer with age. Properly maintaining your pH\/ORP electrode will give you fast, accurate results for longer. So, be sure to order the Milwaukee Maintenance Kit code\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePH-Main\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eat checkout time!  This will be needed to help clean and condition the pH electrode before use!\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStorage\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eWhen not in use, store the meter and EC probe in a safe area to avoid damage. The EC probe is stored dry.  Store the pH probe in storage solution MA9015. Only use tap water short-term if\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMA9015\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis not imediatly availalbe and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNEVER store in distilled Water (DI) or Reverse Osmosis (RO) water. This will damage the sensitivity of the probe.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eCleaning\u003c\/h3\u003e\n\u003cp\u003eResidue from the sample can impact the sensitivity of the sensing bulb and clog the junction. This is especially true if the sample has a lot of organic material. We recommend regularly soaking your electrode in cleaning solution\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/milwaukeeinstruments.com\/milwaukee-ma9016-cleaning-solution-for-ph-\/-orp-electrodes\/\"\u003eMA9016\u003c\/a\u003e\u003cspan\u003e \u003c\/span\u003efor about 20 minutes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe MW180 MAX is easy 1 point EC\/TDS\/NaCl calibration for ease-of-use, up to 3 point pH calibration and two point temperature calibration for best accuracy in (ATC).  Calibrating regularly is best to keep your MI180 5-in-1 MAX Bench meter accurate for all your readings. \u003c\/p\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003epH Range: -2.00 to 20.00 pH \/ -2.000 to 20.000 pH\u003c\/li\u003e\n\u003cli\u003emV Range: ±699.9 mV \/ ±2000 mV\u003c\/li\u003e\n\u003cli\u003eEC Range: 0.00 to 29.99 uS\/cm \/ 30.0 to 299.9 uS\/cm\u003c\/li\u003e\n\u003cli\u003eEC Range: 300 to 2999 uS\/cm\u003c\/li\u003e\n\u003cli\u003eEC Range: 3.00 to 29.99 mS\/cm \/ 30.0 to 200.0 mS\/cm\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eEC Range: up to 500.0 mS\/cm (uncompensated EC)*\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003eTDS Range: 0.00 to 14.99 ppm (mg\/L)\u003c\/li\u003e\n\u003cli\u003eTDS Range: 15.0 to 149.9 ppm (mg\/L) \/ 150 to 1499 ppm (mg\/L)\u003c\/li\u003e\n\u003cli\u003eTDS Range: 1.50 to 14.99 ppt (g\/L) \/ 15.0 to 100.0 ppt (g\/L)\u003c\/li\u003e\n\u003cli\u003eTDS Range: up to 400 g\/L (uncompensated TDS)* (with 0.80 factor)\u003c\/li\u003e\n\u003cli\u003eNaCl Range: 0.0 to 400.0%\u003c\/li\u003e\n\u003cli\u003eTemp. Range: -20.0 to 120.00°C (-4.0 to 248.0°F)\u003c\/li\u003e\n\u003cli\u003epH Resolution: 0.01 pH \/ 0.001 pH\u003c\/li\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003cli\u003emV Resolution: 0.1 mV \/ 1 mV\u003c\/li\u003e\n\u003cli\u003eEC Resolution: 0.01 uS\/cm \/ 0.1 uS\/cm \/ 1 uS\/cm\u003c\/li\u003e\n\u003cli\u003eEC Resolution: 0.01 mS\/cm \/ 0.1 mS\/cm\u003c\/li\u003e\n\u003cli\u003eTDS Resolution: 0.01 ppm (mg\/L) \/ 0.1 ppm (mg\/L) \/ 1 ppm (mg\/L)\u003c\/li\u003e\n\u003cli\u003eTDS Resolution: 0.01 ppt (g\/L) \/ 0.1 ppt ( g\/L)\u003c\/li\u003e\n\u003cli\u003eNaCl Resolution: 0.1%\u003c\/li\u003e\n\u003cli\u003eTemperature Resolution: 0.1°C \/ (0.1°F)\u003c\/li\u003e\n\u003cli\u003eAccuracy @ 20°C \/ 68°F\u003c\/li\u003e\n\u003cli\u003epH: ±0.01 \/ ±0.002 pH\u003c\/li\u003e\n\u003cli\u003emV: ±0.2 mV \/ ±1 mV\u003c\/li\u003e\n\u003cli\u003eEC: ±1% of reading \/ ±0.05 uS\/cm or 1 digit, whichever is greater\u003c\/li\u003e\n\u003cli\u003eTDS: ±1% of reading \/ ±0.03 ppm or 1 digit, whichever is greater\u003c\/li\u003e\n\u003cli\u003eNaCl: ±1% of reading\u003c\/li\u003e\n\u003cli\u003eTemperature: ±0.4°C (±0.8°F)\u003c\/li\u003e\n\u003cli\u003eRel mV offset: ±2000 mV\u003c\/li\u003e\n\u003cli\u003eCalibration\u003c\/li\u003e\n\u003cli\u003epH: 1, 2 or 3 calibration points, with 7 memorized buffers: 1.68, 4.01, 6.86, 7.01, 9.18, 10.01 and 12.45\u003c\/li\u003e\n\u003cli\u003eEC\/TDS: 1 point slope calibration, 6 standards: 84 uS\/cm, 1413 uS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm \/ 1 point offset calibration: 0.00 uS\/cm\u003c\/li\u003e\n\u003cli\u003eNaCl: 1 point, with MA9066 salinity calibration solution\u003c\/li\u003e\n\u003cli\u003eTemperature: 2 points, 0 and 50°C (32 and 122°F)\u003c\/li\u003e\n\u003cli\u003eTemperature Compensation: Automatic or manual from -20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/li\u003e\n\u003cli\u003eConductivity temperature coefficient: Selectable 0.00 to 6.00 % \/ °C (EC and TDS only)\u003c\/li\u003e\n\u003cli\u003eTDS factor: 0.40 to 0.80 \/ Default value: 0.50\u003c\/li\u003e\n\u003cli\u003epH Probe: MA917B\/1 (included)\u003c\/li\u003e\n\u003cli\u003eORP Electrode: (Sold Separately)\u003c\/li\u003e\n\u003cli\u003eTemperature Probe: MA831R (included)\u003c\/li\u003e\n\u003cli\u003eEC Probe: MA814DB\/1 (4 ring, included)\u003c\/li\u003e\n\u003cli\u003eLogging-On-Demand: Maximum 50 samples for each range: (pH, mV \/Rel mV, EC, TDS, NaCl)\u003c\/li\u003e\n\u003cli\u003ePC Connectivity: RS232\/USB opto isolated\u003c\/li\u003e\n\u003cli\u003ePower Supply: 12 VDC adapter (included)\u003c\/li\u003e\n\u003cli\u003eDimensions: 230 x 160 x 95 mm (9.0 x 6.3 x 3.7 inches)\u003c\/li\u003e\n\u003cli\u003eEnvironment: 0 to 50°C \/ 32 to 122°F; max RH 95%\u003c\/li\u003e\n\u003cli\u003eWeight: 0.9 kg \/ 2.00 lbs.\u003c\/li\u003e\n\u003cli\u003eWarranty: 3 years Meter\u003c\/li\u003e\n\u003cli\u003e*Uncompensated conductivity (TDS) is the conductivity (or TDS) value without temperature compensation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!----\u003e","brand":"MILWAUKEE INSTRUMENTS","offers":[{"title":"Default Title","offer_id":41038735245399,"sku":"MW180US","price":1017.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1555\/0581\/files\/MW180-MAX__42735.jpg?v=1718126539","url":"https:\/\/getultimatenow.com\/products\/milwaukee-mw180-max-5-in-1-bench-meter-ph-orp-ec-tds-nacl-temp-logging","provider":"Get Ultimate Now ","version":"1.0","type":"link"}