{"product_id":"apera-pc850-portable-ph-conductivity-tds-meter-kit","title":"Apera Instruments PC850 Portable pH\/Conductivity\/TDS Meter Kit | IP57 Waterproof, Multi-Parameter","description":"\u003cp\u003e\u003cimg src=\"https:\/\/cfrouting.zoeysite.com\/cdn-cgi\/image\/format=auto,quality=85,fit=scale-down\/https:\/\/s3.amazonaws.com\/zcom-media\/sites\/a0i0L00000VJHGsQAP\/media\/mediamanager\/PC850_app.jpg\" alt=\"PC850_app\"\u003e\u003c\/p\u003e\n\u003cdiv id=\"cp-63351953391e4293521052\" class=\"cp-63351953391e4293521052 zoeydev-info-banner-preset7 zoeydev-component-info-banner-preset7 zoey-core-infobanner pix-design-component\"\u003e\n\u003cdiv class=\"component-content\"\u003e\n\u003cdiv class=\"infobanner__container\"\u003e\n\u003cdiv class=\"infobanner__paragraph-container infobanner__paragraph-container__image-position-right\"\u003e\n\u003cdiv class=\"infobanner__paragraph-container-content infobanner__paragraph-container-content__image-position-right\"\u003e\n\u003cdiv class=\"infobanner__paragraph-content std\"\u003e\n\u003cp class=\"a-spacing-base\"\u003eApera Instruments Value Series PC850 Portable pH\/Conductivity Meter Kit is designed for professional pH and conductivity measurement in the field with a variety of practical functions and features in a rugged structure. Up to three electrodes can be connected to the meter simultaneously for the measurement of multiple parameters, including pH, conductivity, TDS, temperature, and ORP.\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eORP measurement is available in mV mode with an ORP probe connected (model 301Pt-C, sold separately).\u003c\/p\u003e\n\u003ch5 class=\"a-spacing-mini a-color-secondary\"\u003eEasy Calibration\u003c\/h5\u003e\n\u003cp class=\"a-spacing-base\"\u003eQuick and easy 1- to 3-point auto. calibration, recognizing pH standards of 1. 68, 4. 00, 7. 00, 10. 01, and 12. 45; conductivity standards of 1413 µS, 12. 88 mS, 84 µS, and 111. 8 mS.\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003eThe slope data will be displayed after completing 2nd and 3rd point calibration, indicating the condition of your pH electrode. The self-diagnosis function ensures calibration will be properly performed.\u003c\/p\u003e\n\u003ch5 class=\"a-spacing-mini a-color-secondary\"\u003eEasy Parameter Setup\u003c\/h5\u003e\n\u003cp class=\"a-spacing-base\"\u003eAuto. lock and auto. power off function available.\u003c\/p\u003e\n\u003cp class=\"a-spacing-base\"\u003epH standard series, pH resolution, stability criteria, temperature unit, conductivity cell constant, reference temperature, and temperature compensation coefficient are all customizable. TDS conversion factor can be set from 0.40 to 1.00.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"cp-6335195338e42254163844\" class=\"cp-6335195338e42254163844 zoeydev-info-banner-preset6 zoeydev-component-info-banner-preset6 zoey-core-infobanner pix-design-component\"\u003e\n\u003cdiv class=\"component-content\"\u003e\n\u003cdiv class=\"container\"\u003e\n\u003cdiv class=\"container-row\"\u003e\n\u003ca class=\"zoey-infobanner\"\u003e\n\u003cdiv class=\"image zoey-component-placement-height\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"banner-content\"\u003e\n\u003ch2\u003e201T-F pH Electrode\u003c\/h2\u003e\n\u003cp\u003epH electrode is the fundamental component that determines the measuring performance of a pH meter. The proprietary lithium glass membrane of Apera 201T-F pH Electrode ensures to provide accurate and stable signals to the PH850 meter such that you can have confidence in the readings you take.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\u003ca class=\"zoey-infobanner\"\u003e\n\u003cdiv class=\"image zoey-component-placement-height\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"banner-content\"\u003e\n\u003ch2\u003eProprietary electrode structure\u003c\/h2\u003e\n\u003cp\u003eA unique junction composed of ceramic and fiber filaments efficiently reduces junction clogging. The built-in temperature sensor tests pH and temperature simultaneously, enabling auto. temp compensation (ATC).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\u003ca class=\"zoey-infobanner\"\u003e\n\u003cdiv class=\"image zoey-component-placement-height\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"banner-content\"\u003e\n\u003ch2\u003epH Sensor Shield\u003c\/h2\u003e\n\u003cp\u003eThe detachable sensor shield protects the sensitive glass membrane from accidental damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\u003ca href=\"https:\/\/aperainst.com\/pc850-portable-phconductivity-meter-kit#\" class=\"zoey-infobanner\"\u003e\n\u003cdiv class=\"image zoey-component-placement-height\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/a\u003e\n\u003cdiv class=\"banner-content\"\u003e\n\u003ca href=\"https:\/\/aperainst.com\/pc850-portable-phconductivity-meter-kit#\" class=\"zoey-infobanner\"\u003e\u003c\/a\u003e\n\u003cdiv id=\"cp-6335195333980811474793\" class=\"cp-6335195333980811474793 zoey-core-group-preset1 zoey-core-component-group-preset1 zoey-core-group pix-design-component product-tab-open\"\u003e\n\u003ca href=\"https:\/\/aperainst.com\/pc850-portable-phconductivity-meter-kit#\" class=\"zoey-infobanner\"\u003e\u003c\/a\u003e\n\u003cdiv class=\"component-content\"\u003e\n\u003ca href=\"https:\/\/aperainst.com\/pc850-portable-phconductivity-meter-kit#\" class=\"zoey-infobanner\"\u003e\u003c\/a\u003e\n\u003cdiv class=\"group-background-image-container zoey-component-placement-height\"\u003e\n\u003ca href=\"https:\/\/aperainst.com\/pc850-portable-phconductivity-meter-kit#\" class=\"zoey-infobanner\"\u003e\u003c\/a\u003e\n\u003cdiv id=\"cp-6335195338a33363506094\" class=\"cp-6335195338a33363506094 zoeydev-info-banner-preset6 zoeydev-component-info-banner-preset6 zoey-core-infobanner pix-design-component\"\u003e\n\u003ca href=\"https:\/\/aperainst.com\/pc850-portable-phconductivity-meter-kit#\" class=\"zoey-infobanner\"\u003e\u003c\/a\u003e\n\u003cdiv class=\"component-content\"\u003e\n\u003ca href=\"https:\/\/aperainst.com\/pc850-portable-phconductivity-meter-kit#\" class=\"zoey-infobanner\"\u003e\u003c\/a\u003e\n\u003cdiv class=\"container\"\u003e\n\u003ca href=\"https:\/\/aperainst.com\/pc850-portable-phconductivity-meter-kit#\" class=\"zoey-infobanner\"\u003e\u003c\/a\u003e\n\u003cdiv class=\"container-row\"\u003e\n\u003ca href=\"https:\/\/aperainst.com\/pc850-portable-phconductivity-meter-kit#\" class=\"zoey-infobanner\"\u003e\u003c\/a\u003e\u003ca class=\"zoey-infobanner\"\u003e\n\u003cdiv class=\"image zoey-component-placement-height\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"banner-content\"\u003e\n\u003ch2\u003eConductivity Electrode\u003c\/h2\u003e\n\u003cp\u003eThe equipped Apera 2301T-S Conductivity Electrode is built with a proprietary firm platinum black cell, which ensures high accuracy (±1% F.S) in an ultra-wide range (0 to 200 mS\/cm or 200,000 µS\/cm). The built-in temp. sensor enables ATC of the meter and the PVC body makes it resistant to corrosions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\u003ca class=\"zoey-infobanner\"\u003e\n\u003cdiv class=\"image zoey-component-placement-height\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"banner-content\"\u003e\n\u003ch2\u003eLarge LCD Screen\u003c\/h2\u003e\n\u003cp\u003eStability icon. Take the reading when the smiley face stays on screen. Icons for finished calibrations Simultaneous temperature display\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\u003ca href=\"https:\/\/aperainst.com\/pc850-portable-phconductivity-meter-kit#\" class=\"zoey-infobanner\"\u003e\n\u003cdiv class=\"banner-content\"\u003e\u003c\/div\u003e\n\u003c\/a\u003e\u003ca class=\"zoey-infobanner\"\u003e\n\u003cdiv class=\"banner-content\"\u003e\n\u003ch2\u003eBuild tough\u003c\/h2\u003e\n\u003cp\u003eThe IP57 water-resistant structure makes the meter ideal for use in harsh environment. The rubber sleeve protects the instrument from general impact and gives you a firm grip.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"cp-6335195337c38149047699\" class=\"cp-6335195337c38149047699 zoey-core-banner-preset4 zoey-core-component-banner-preset4 zoey-core-banner pix-design-component full-width-element js__full-width-element-initted\"\u003e\n\u003cdiv class=\"component-content\"\u003e\n\u003cdiv class=\"zoey-component-placement-height\"\u003e\u003cimg src=\"https:\/\/cfrouting.zoeysite.com\/cdn-cgi\/image\/format=auto,quality=85,fit=scale-down\/https:\/\/s3.amazonaws.com\/zcom-media\/sites\/a0i0L00000VJHGsQAP\/media\/mediamanager\/pc850_kit.jpg\" alt=\"pc850_kit\" title=\"\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"zoey-component-placement-height\"\u003e\n\u003ch4\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\" width=\"47\"\u003e\n\u003cp\u003e\u003cspan\u003epH\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"111\"\u003e\n\u003cp\u003e\u003cspan\u003eMeasuring Range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"260\"\u003e\n\u003cp\u003e\u003cspan\u003e（0 to 14.00）pH\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"111\"\u003e\n\u003cp\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"260\"\u003e\n\u003cp\u003e\u003cspan\u003e0.1\/0.01 pH\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"111\"\u003e\n\u003cp\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"260\"\u003e\n\u003cp\u003e\u003cspan\u003e±0.01 pH ±1 digit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"111\"\u003e\n\u003cp\u003e\u003cspan\u003eTemperature Compensation Range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"260\"\u003e\n\u003cp\u003e\u003cspan\u003e(0 to 100)˚C (Auto. or Manual)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"111\"\u003e\n\u003cp\u003e\u003cspan\u003eCalibration point\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"260\"\u003e\n\u003cp\u003e\u003cspan\u003e1 to 3 points\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" width=\"47\"\u003e\n\u003cp\u003e\u003cspan\u003emV\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"111\"\u003e\n\u003cp\u003e\u003cspan\u003eMeasuring Range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"260\"\u003e\n\u003cp\u003e\u003cspan\u003e±1000mV\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"111\"\u003e\n\u003cp\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"260\"\u003e\n\u003cp\u003e\u003cspan\u003e1mV\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"111\"\u003e\n\u003cp\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"260\"\u003e\n\u003cp\u003e\u003cspan\u003e±0.2% FS ±1 digit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\" width=\"47\"\u003e\n\u003cp\u003e\u003cspan\u003eCond.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"111\"\u003e\n\u003cp\u003e\u003cspan\u003eMeasuring Range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"260\"\u003e\n\u003cp\u003e\u003cspan\u003eConductivity：0~200 mS\/cm, divided into five ranges, automatically switch measuring range.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e(0 to 19.99) μS\/cm;\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e(20.0 to 199.9) μS\/cm; \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e(200 to 1999) μS\/cm;\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e(2.00 to 19.99) mS\/cm;\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e(20.0 to 199.9) mS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTDS: (0 to 100) g\/L;\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"111\"\u003e\n\u003cp\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"260\"\u003e\n\u003cp\u003e\u003cspan\u003e0.01\/0.1\/1μS\/cm  0.01\/0.1 mS\/cm\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"111\"\u003e\n\u003cp\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"260\"\u003e\n\u003cp\u003e\u003cspan\u003e±1.0% FS ±1 digit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"111\"\u003e\n\u003cp\u003e\u003cspan\u003eTemperature Compensation Range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"260\"\u003e\n\u003cp\u003e\u003cspan\u003e (0 to 50)˚C (Auto. or Manual)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"111\"\u003e\n\u003cp\u003e\u003cspan\u003eCell constant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"260\"\u003e\n\u003cp\u003e\u003cspan\u003e0.1\/1\/10 cm\u003csup\u003e-1\u003c\/sup\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\" width=\"47\"\u003e\n\u003cp\u003e\u003cspan\u003eTemp.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"111\"\u003e\n\u003cp\u003e\u003cspan\u003eMeasuring Range\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"260\"\u003e\n\u003cp\u003e\u003cspan\u003e0 to 100℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"111\"\u003e\n\u003cp\u003e\u003cspan\u003eResolution\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"260\"\u003e\n\u003cp\u003e\u003cspan\u003e0.1℃\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"111\"\u003e\n\u003cp\u003e\u003cspan\u003eAccuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"260\"\u003e\n\u003cp\u003e\u003cspan\u003e±0.5℃±1 digit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch4\u003e\u003cstrong\u003eOther Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ctable border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"157\"\u003e\n\u003cp\u003e\u003cspan\u003eData Storage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"323\"\u003e\u003cspan\u003eN\/A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"157\"\u003e\n\u003cp\u003e\u003cspan\u003eStorage Content\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"323\"\u003e\n\u003cp\u003e\u003cspan\u003eN\/A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"157\"\u003e\n\u003cp\u003e\u003cspan\u003ePower\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"323\"\u003e\n\u003cp\u003e\u003cspan\u003e3* AA alkaline batteries\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"157\"\u003e\n\u003cp\u003e\u003cspan\u003eDimension \u0026amp; Weight\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"323\"\u003e\n\u003cp\u003e\u003cspan\u003eMeter: (88*170*33)mm \/ 313g\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCase: (360*270*76)mm \/ 1.6kg\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"157\"\u003e\u003cspan\u003eConnector \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"323\"\u003e\n\u003cp\u003e\u003cspan\u003eBNC for pH and ORP; RCA for temperature, 8-pin for conductivity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"157\"\u003e\u003cspan\u003e What's in the box?\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"323\"\u003e\n\u003cspan\u003e PC850 meter, 201T-F pH\/temp. electrode,  2301T-S conductivity\/temp. electrode, electrode clip, 50ml of pH buffers (4.00, 7.00\u003c\/span\u003e, 10.01), 50ml of conductivity standards (84µS,1413µS, 12.88mS), screwdriver (for battery replacement), instruction manual, carrying case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Apera Instruments","offers":[{"title":"Default Title","offer_id":44274208145495,"sku":"PC850","price":499.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1555\/0581\/files\/pc850_1.webp?v=1789329878","url":"https:\/\/getultimatenow.com\/products\/apera-pc850-portable-ph-conductivity-tds-meter-kit","provider":"Get Ultimate Now ","version":"1.0","type":"link"}