{"product_id":"apera-instruments-ec9500-research-grade-benchtop-conductivity-meter-kit","title":"Apera Instruments EC9500 Research-grade Benchtop Conductivity Meter Kit","description":"\u003cul class=\"tab-content\"\u003e\n\u003cli\u003e\n\u003cdiv id=\"cp-5aabd8b15c9b1448224175\" class=\"cp-5aabd8b15c9b1448224175 zoey-core-tabs-tab zoey-core-component-tabs-tab zoey-core-tabs-tab pix-design-component\"\u003e\n\u003cdiv class=\"component-content\"\u003e\n\u003cdiv class=\"group-background-image-container zoey-component-placement-height\"\u003e\n\u003cdiv id=\"cp-5aabdacab9085078744552\" class=\"cp-5aabdacab9085078744552 zoeydev-product-description-preset1 zoeydev-component-product-description-preset1 zoey-core-product-description pix-design-component\"\u003e\n\u003cdiv class=\"component-content\"\u003e\n\u003cdiv class=\"product-description std\" itemprop=\"description\"\u003e\n\u003ch3\u003e\u003cb\u003eInstrument Features\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eAdvanced, Intuitive Interface — \u003c\/b\u003ePlain-language menus and graphic screen prompts eliminate the need for extensive manual reading or training. Multi-language support includes English, German, Spanish, and Chinese.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003ePowerful Data Management —\u003c\/b\u003eManual\/automatic data logger with\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e2000 sets\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eof GLP-compliant data storage, including electrode ID, user ID, sample ID, company name, and optional calibration password protection.\u003c\/p\u003e\n\u003cp class=\"p2\"\u003eExport data via USB to PC or a mini-printer (sold separately).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003ei-Guide On-Screen Tutorials — \u003c\/b\u003ePress the “i” key at any time for step-by-step setup and calibration instructions displayed directly on the screen.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eApera TestBench Included — \u003c\/b\u003eIntegrated workstation with a flexible electrode holder, intelligent magnetic stirrer, and buffer organizers — dramatically streamlines calibration and measurement workflows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConductivity\/TDS\/Salinity\/Resistivity Measurement\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp class=\"p1\"\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003e2401T-F Conductivity Electrode (Included) — \u003c\/b\u003eGlass-body delivers high-accuracy measurements from\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e0 to 200 mS\/cm\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eat\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e±0.5% F.S\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003eaccuracy.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eFlexible Conductivity Calibration — \u003c\/b\u003e1 to 4 point auto. calibration with standard solutions (84 µS\/cm, 1413 µS\/cm, 12.88 mS\/cm, 111.8 mS\/cm) or user-defined standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eQuick Parameter Switching — \u003c\/b\u003eOne-tap conversion among\u003cspan\u003e \u003c\/span\u003e\u003cb\u003econductivity\u003c\/b\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eTDS\u003c\/b\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cb\u003esalinity\u003c\/b\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eresistivity\u003c\/b\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eMultiple Salinity Modes — \u003c\/b\u003eSelect from\u003cspan\u003e \u003c\/span\u003e\u003cb\u003egeneral salinity\u003c\/b\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cb\u003esaltwater salinity\u003c\/b\u003e, or\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eNaCl salinity\u003c\/b\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"p1\"\u003e\u003cb\u003eBroad Compatibility — \u003c\/b\u003eStandard\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eBNC conductivity connector\u003c\/b\u003e; compatible with\u003cspan\u003e \u003c\/span\u003e\u003cb\u003e2310T-F\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e(up to 2000 mS\/cm) and\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eDJS-0.1-F\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003efor high-purity water. Uses\u003cspan\u003e \u003c\/span\u003e\u003cb\u003eRCA temperature connector (NTC 30KΩ)\u003c\/b\u003e.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eParameter Settings Menu\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cbr\u003e\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eMenu\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eOptions\u003c\/th\u003e\n\u003cth\u003eDefault\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"10\"\u003eConductivity \/ TDS \/ Salinity\u003c\/td\u003e\n\u003ctd\u003eCell Constant\u003c\/td\u003e\n\u003ctd\u003e10 \/ 1.0 \/ 0.1\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Standard\u003c\/td\u003e\n\u003ctd\u003eStandard \/ CH \/ User\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Info\u003c\/td\u003e\n\u003ctd\u003eCheck \/ Print\u003c\/td\u003e\n\u003ctd\u003eCheck\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Reminder\u003c\/td\u003e\n\u003ctd\u003eOff \/ Hour \/ Day\u003c\/td\u003e\n\u003ctd\u003eOff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Temp.\u003c\/td\u003e\n\u003ctd\u003e15–30°C\u003c\/td\u003e\n\u003ctd\u003e25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp. Compensation Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00–10.00%\u003c\/td\u003e\n\u003ctd\u003e2.00%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Factor\u003c\/td\u003e\n\u003ctd\u003e0.40–1.00\u003c\/td\u003e\n\u003ctd\u003e0.71\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Type\u003c\/td\u003e\n\u003ctd\u003eLinear \/ NaCl \/ Saltwater (Seawater)\u003c\/td\u003e\n\u003ctd\u003eLinear\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode ID\u003c\/td\u003e\n\u003ctd\u003eCustom Input\u003c\/td\u003e\n\u003ctd\u003e---\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBack to Factory Default\u003c\/td\u003e\n\u003ctd\u003eNo \/ Yes\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003eData Management\u003c\/td\u003e\n\u003ctd\u003eLogging Destination\u003c\/td\u003e\n\u003ctd\u003eMemory \/ Printer \/ PC\u003c\/td\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Mode\u003c\/td\u003e\n\u003ctd\u003eManual \/ Auto\u003c\/td\u003e\n\u003ctd\u003eManual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinting Format\u003c\/td\u003e\n\u003ctd\u003eSimple \/ Complete\u003c\/td\u003e\n\u003ctd\u003eSimple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDelete Data\u003c\/td\u003e\n\u003ctd\u003eYes \/ No\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"9\"\u003eGeneral Settings\u003c\/td\u003e\n\u003ctd\u003eSample ID\u003c\/td\u003e\n\u003ctd\u003eCustom Input\u003c\/td\u003e\n\u003ctd\u003e---\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser ID\u003c\/td\u003e\n\u003ctd\u003eCustom Input\u003c\/td\u003e\n\u003ctd\u003e---\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompany Name\u003c\/td\u003e\n\u003ctd\u003eCustom Input\u003c\/td\u003e\n\u003ctd\u003e---\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Password\u003c\/td\u003e\n\u003ctd\u003eCustom Input\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Info\u003c\/td\u003e\n\u003ctd\u003eSimple \/ Complete\u003c\/td\u003e\n\u003ctd\u003eSimple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Hold\u003c\/td\u003e\n\u003ctd\u003eOn \/ Off\u003c\/td\u003e\n\u003ctd\u003eOff\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Unit\u003c\/td\u003e\n\u003ctd\u003e°C \/ °F\u003c\/td\u003e\n\u003ctd\u003e°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDate Format\u003c\/td\u003e\n\u003ctd\u003eYYYY-MM-DD \/ MM-DD-YYYY \/ DD-MM-YYYY\u003c\/td\u003e\n\u003ctd\u003eYYYY-MM-DD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguage\u003c\/td\u003e\n\u003ctd\u003eEnglish \/ German \/ Spanish \/ French \/ Italian \/ Chinese \/ Japanese\u003c\/td\u003e\n\u003ctd\u003eEnglish\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cb\u003e\u003cbr\u003e\u003c\/b\u003e\n\u003ch3\u003e\u003cb\u003eWhat's in the Kit?\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eQuantity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC9500 pH\/Conductivity Meter\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e606 Test-Bench (with flexible electrode holder)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2401T-F Conductivity Electrode (ATC, K=1.0)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Calibration Solutions (84 µS \/ 1413 µS \/ 12.88 mS, 50mL each)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Power Cable\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB Cable\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC-Link 9500 Flash Drive\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9V Adapter\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Vials\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eL200 Stir Beads\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Manual\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol\u003e \u003ccol\u003e \u003ccol\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"9\"\u003e\n\u003cp\u003eConductivity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRange\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0~2000 mS\/cm, divided into five ranges, automatically switch measuring range.\u003c\/p\u003e\n\u003cp\u003e(0 to 19.99) μS\/cm;\u003c\/p\u003e\n\u003cp\u003e(20.0 to 199.9) μS\/cm; \u003c\/p\u003e\n\u003cp\u003e(200 to 1999) μS\/cm;\u003c\/p\u003e\n\u003cp\u003e(2.00 to 19.99) mS\/cm;\u003c\/p\u003e\n\u003cp\u003e(20.0 to 199.9) mS\/cm\u003c\/p\u003e\n\u003cp\u003e(200.0 to 2000) mS\/cm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.01\/0.1\/1μ\/cm; 0.01\/0.1\/1 mS\/cm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAccuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±0.5% F.S ± digit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTemp. Compensation Range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0 to 50°C (auto. or manual)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCell Constant\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.1\/1\/10 cm-1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eReference Temp.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e15 to 30°C (adjustable)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTemp. Compensation Coefficient\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.00 to 10.00% (adjustable)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eCalibration Points\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1 to 4 points\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eStandard Series Options\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eStandard, CH, User-Define\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003e\n\u003cp\u003eTDS\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRange\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.00 mg\/L to 1000 g\/L\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.01\/0.1\/1mg\/L; 0.01\/0.1\/1 g\/L\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAccuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±0.5% F.S\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTemp. Compensation Range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0 to 50°C (auto. or manual)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTDS Factor\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.40 to 1.00 (adjustable)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"5\"\u003e\n\u003cp\u003eSalinity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRange\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.00 to 100 ppt\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.01\/0.1 ppt\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAccuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±0.5% F.S\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTemp. Compensation Range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0 to 50°C (auto. or manual)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eSalinity Type\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eLinear \/ NaCl \/ Saltwater\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\"\u003e\n\u003cp\u003eResistivity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRange\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.00 Ω·m to 100MΩ·m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.1\/1 Ω·m; 0.01\/0.1\/1KΩ·m; 0.1 MΩ·m\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAccuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±0.5% F.S\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eTemp. Compensation Range\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0 to 50°C (auto. or manual)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\n\u003cp\u003eTemperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003eRange\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e-10.0 to 110.0°C\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.1°; 0.1\/1°\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eAccuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e±.5°\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"APERA Instruments","offers":[{"title":"Default Title","offer_id":44152836030551,"sku":"AI5632","price":730.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1555\/0581\/files\/ec9500-2_1.avif?v=1786558328","url":"https:\/\/getultimatenow.com\/products\/apera-instruments-ec9500-research-grade-benchtop-conductivity-meter-kit","provider":"Get Ultimate Now ","version":"1.0","type":"link"}